Capsule Home Range

Moyag Capsule Homes Ireland

A factory-built capsule dwelling of approximately 39 m², delivered and crane-installed on your site as a single unit. 11.5 × 3.4 × 3.4 m, single storey with one separate bedroom, designed for auxiliary habitable dwelling use.

The Moyag capsule is a distinct product, documented separately from the Chapter One, Chapter Two and Chapter Three series.

New Chapter Homes branded modular capsule home photographed at the manufacturing facility.
New Chapter Homes — Modular Capsule Home at Our Manufacturing Partner's Facility.

Moyag capsule

One documented unit

A single capsule format, approximately 39 m², supported by one technical compliance statement and one engineering review. The U-values and construction details on this page apply to this unit and to nothing else.

Chapter series

Separate product family

Chapter One, Chapter Two and Chapter Three are separate products with their own specifications and their own documentation. Nothing on this page applies to them.

Technical Documentation

Documented, Reviewed, Traceable

The technical file prepared by Hangzhou Moyag Technology Co., Ltd sets out how the design addresses structure, fire safety, ventilation, energy, access and use, and building services. It is accompanied by a letter from Coughlan Consulting Engineering, the project engineer, confirming their appointment and preparation of the compliance documentation.

Manufacturer statement

Hangzhou Moyag Technology Co., Ltd

MOYAG-COMP-2026-001 V2.2 · 24 September 2026

Engineering review

Coughlan Consulting Engineering

Ref. 26196 · 2 October 2026 · Robert Coughlan, BE, CEng, FIEI, MIStructE

Scope: this documentation applies to the Moyag capsule dwelling described on this page only. It does not apply to the Chapter One, Chapter Two or Chapter Three series, or to any other product. It is design-stage technical material for this unit: not a BER certificate, not independent certification of the completed dwelling, not NSAI accreditation, and not a blanket approval under the Building Regulations. The full technical file is available on request.

Capsule Home Specification

Moyag Capsule Home — Documented Design

Approximately 39 m² modular capsule dwelling. This specification applies to this unit alone and is documented separately from the Chapter One, Chapter Two and Chapter Three series.

Engineering review

Coughlan Consulting Engineering — ref. 26196

2 October 2026 · Robert Coughlan, BE, CEng, FIEI, MIStructE

Technical compliance statement

MOYAG-COMP-2026-001 V2.2

24 September 2026 · Chen Haijie, General Manager

Product

Auxiliary Habitable Dwelling (AHD)

Overall Dimensions

11.5 × 3.4 × 3.4 m

Envelope

Galvanised steel chassis and frame, aluminium cladding, PIR insulation

Frame

Q235 / Q355 hot-dip galvanised steel frame

Configuration

Single storey, one separate bedroom

Installation

Pre-delivery crane lift from a 13.5 m trailer, minimum 25 t crane

Documented U-Values

Design values stated in the manufacturer's compliance statement and reviewed by the project engineer. They describe the design of this unit; they are not a measured or certified as-built performance figure.

Roof
0.14W/m²K
0.16
150 mm PIR insulation to roof build-up
External Walls
0.15W/m²K
0.21
120 mm PIR with mineral-wool infill
Ground Floor
0.16W/m²K
0.18
120 mm PIR insulation
Windows and Doors
≤1.20W/m²K
1.40
Low-E 6+12A+6 double glazing as standard; triple glazing where specified locally

Part L 2021 maximum values shown for comparison. Airtightness: design target ≤3 m³/(h·m²) against a limit of ≤5 m³/(h·m²). Post-installation blower-door test proposed; result per dwelling.

Requirements Addressed

Part A

Structure

  • Eurocode-based structural design with finite-element analysis
  • Wind analysis at 52 m/s; lifting analysis at 79.1 MPa against a 156.6 MPa limit
  • Four-point lifting arrangement
  • Q355 steel at critical members

Part B

Fire Safety

  • Wall and ceiling linings classified A2-s1,d0
  • A1 mineral-wool wall insulation where specified
  • Grade D / LD2 interlinked alarms, smoke and kitchen heat detection
  • Escape window with 0.48 m² clear opening and 950 mm sill
  • Outward-opening 800 × 2,100 mm final exit
  • Safety glazing to EN 12150

Part F

Ventilation

  • Extract fans with background ventilators, 24,500 mm² total
  • Purge ventilation provision
  • Component testing to I.S. EN 13141 series
  • On-site performance verification to I.S. EN 14134 at commissioning

Part L

Energy

  • Documented design U-values as tabulated above
  • Heat-pump air conditioner, COP ≥3.4
  • Electric water heater
  • Roof prepared for an optional 2 kWp photovoltaic array
  • nZEB indicators identified as targets the design is intended to support
  • No calculated DEAP or BER result is provided

Part M

Access & Use

  • 800 × 2,100 mm entrance opening
  • Level threshold with a rise not exceeding 15 mm
  • WC at entrance level
  • Accessible switch and socket positioning

Services

Electrical & Plumbing

  • I.S. 10101:2020 electrical installation
  • 30 mA Type A RCD and Type 2 surge protection device
  • English-labelled consumer unit and factory electrical testing
  • Final connection by a Safe Electric registered electrician
  • Plumbing to EN 806 and EN 12056, thermostatic mixing to EN 1111

Structural Warranty

10-year structural warranty on the completed dwelling, subject to written warranty terms. Component and finish covers, where offered, are stated separately in the warranty terms and are not described as structural.

What this documentation is not

  • Not a BER certificate and not evidence of any BER rating.
  • Not a product certification of the completed dwelling.
  • Not a planning permission or a planning exemption determination.
  • Not a blanket Building Regulations approval; compliance is confirmed per project under BCAR.
  • Does not cover Chapter One, Chapter Two or Chapter Three, whose specifications remain held pending their own documentation.

Compliance

Confirmed Per Project

Building Regulations compliance is established for each individual project, not by the product documentation alone. It depends on the design as built, the site, the foundations and services, installation and commissioning, and the applicable Building Control requirements — including the role of the Assigned Certifier under BCAR.

A BER certificate is issued per dwelling by an independent registered BER assessor following assessment of the completed home. The documented design U-values on this page describe the design; they are not a BER rating, and no A1 or A2 rating is claimed for this product.

Final airtightness is verified by blower-door test on the completed dwelling, and ventilation by commissioning to I.S. EN 14134.

Enquire About a Moyag Capsule

Tell us about your site and how you intend to use the unit. We will confirm suitability, outline the project-specific compliance steps and prepare a written quotation.

Your Privacy & Cookie Consent

In accordance with the EU General Data Protection Regulation (GDPR) and the ePrivacy Directive, we use cookies and similar technologies to enhance your browsing experience, analyse site traffic, and personalise content. By clicking Accept All, you consent to our use of cookies. You may Decline to only allow strictly necessary cookies. For full details, see our Privacy Policy and Cookie Policy.